comparison of corneal biomechanics in sjögren’s syndrome and non-sjögren’s syndrome dry eyes by scheimpflug based device
Clicks: 364
ID: 188199
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
364 views
42 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #11 of 79 articles by views in The Classical Review
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
AIM: To compare the corneal biomechanics of Sjögren’s syndrome (SS) and non-SS dry eyes with Corneal Visualization Scheimpflug Technology (CorVis ST).
METHODS: Corneal biomechanics and tear film parameters, namely the Schirmer I test value, tear film break-up time (TBUT) and corneal staining score (CSS) were detected in 34 eyes of 34 dry eye patients with SS (SSDE group) and 34 dry eye subjects without SS (NSSDE group) using CorVis ST. The differences of the above parameters between the two groups were examined, and the relationship between corneal biomechanics and tear film parameters were observed.
RESULTS: The differences in age, sex, intraocular pressure (IOP) and central corneal thickness (CCT) were not significant between the two groups (P>0.05). The tear film parameters had significant differences between the SSDE group and NSSDE group (all P<0.05). Patients in the SSDE group had significantly lower A1-time and HC-time, but higher DA (P=0.01, 0.02, and 0.02, respectively) compared with the NSSDE group. In the SSDE group, DA was negatively correlated with TBUT (rho=-0.38, P=0.03); HC-time was negatively correlated with CSS (rho=-0.43, P=0.02). In the NSSDE group, HC-time was again negatively correlated with CSS (rho=-0.39, P=0.02).
CONCLUSION: There are differences in corneal biomechanical properties between SSDE and NSSDE. The cornea of SSDE tends to show less “stiffness”, as seen by a significantly shorter A1-time and HC-time, but larger DA, compared with the cornea of NSSDE. Biomechanical parameters can be influenced by different tear film parameters in both groups.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (131 words).
Try re-searching for a better abstract.
| Reference Key |
long2017internationalcomparison
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Qin Long;Jing-Yi Wang;Dong Xu;Ying Li |
| Journal | The Classical Review |
| Year | 2017 |
| DOI |
10.18240/ijo.2017.05.08
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.