anatomia do sulco da artéria vertebral vertebral artery groove anatomy
Article Quality & Performance Metrics
Readership in this journal
SteadyRanked #15 of 45 articles by views in current opinion in food science
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
INTRODUCTION: Several surgical techniques have been carried through in the skull-cervical region due to various pathologies. During the surgical access to this region, a potential risk of iatrogenic injury of the vertebral artery exists, related to extended lateral access and the inadequate evaluation of the local anatomy. Variations in the groove of the vertebral artery lead to a greater risk of vascular injury during surgery. Preoperative image study of the vertebral artery anatomy and its groove has been realized to enhance surgical safety. OBJECTIVE: to study the morphometry of atlas vertebral artery on computed tomography scan images of the vertebral artery groove (VAG) in 30 dry atlas. METHODS: VAG and its relationship with the midline were evaluated through eight linear and two angular measures, bilaterally. The average, maximum and minimum values, and standard deviation were calculated for each parameter. RESULTS: VAG has shown to be wider and thicker on the left side (p<0,05). CONCLUSION: our data suggest that the posterior and superior dissection of the posterior arch must be made at lateral distance of 11,2mm and 7,4mm to the midline in order to provide safety during the procedure.
| Reference Key |
carvalho2009actaanatomia
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Max Franco de Carvalho;Roberta Teixeira Rocha;João Tiago Silva Monteiro;Carlos Umberto Pereira;Helton Luiz Aparecido Defino |
| Journal | current opinion in food science |
| Year | 2009 |
| DOI |
10.1590/S1413-78522009000100010
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.