flow characteristics of the medtronic corevalve: difficulties estimating aortic valve cross-sectional area following transcatheter aortic valve implantation

Clicks: 165
ID: 185980
2014
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
Background: Echocardiographic evaluation after transcatheter aortic valve implantation (TAVI) includes estimation of effective orifice area (EOA). EOA calculation depends on sub-valvular stroke volume (SV), which depends on sub-valvular diameter and velocity time integral (VTI). The Medtronic CoreValve area changes throughout its length. We aimed to (i) compare SV at two sites of flow acceleration: ‘pre-stent’ and ‘in-stent, pre-valve’, (ii) assess effects of possible differences in sub-valvular SV on EOA, and (iii) assess agreement of measurement of EOA calculation after CoreValve TAVI. Methods: We studied 43 patients after CoreValve implantation. All had transthoracic echocardiography 5-7 days after TAVI. Sub-valvular SV was measured ‘pre-stent’ and ‘in-stent, pre-valve’. Measurement agreement was assessed by root mean square (RMS) differences and Bland-Altman analyses. Results: SV was consistently higher ‘in-stent, pre-valve’ compared with ‘pre-stent’ (62±20ml vs. 53±19ml, p<0.001), so that EOA was correspondingly larger using ‘in-stent, pre-valve’ measurements (1.7±0.5cm2 vs. 1.4±0.5cm2, p<0.001). Between-observer RMS difference for calculation of EOA was higher ‘in-stent, pre-valve’ compared to ‘pre-stent’ (0.53 cm2 vs. 0.23cm2, difference from zero 0.17, p=0.002). Though sub-valvular diameter measurements were variable, VTI variability was additionally higher ‘in-stent, pre-valve’ compared to ‘pre-stent’ (0.42cm vs. 0.6cm, difference from zero -1.74, p=0.11). Conclusion: Calculation of EOA after CoreValve TAVI is highly dependent on sub-valvular sample position. EOA may be underestimated using ‘pre-stent’ SV, and overestimated using ‘in-stent, pre-valve’ SV. Limitations in SV reproducibility suggests EOA should be used in conjunction with other indices of valve function in serial assessment of CoreValve function following TAVI.
Reference Key
duncan2014internationalflow Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Alison Duncan;Eric Lim;Sarah Barker;Carlo Di Mario;Simon Davies;Neil Moat
Journal transplant infectious disease : an official journal of the transplantation society
Year 2014
DOI
https://doi.org/10.17987/icfj.v1i3.38
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.