evaluation of radiation protection in nuclear medicine department in namazi hospital according to global accepted standards

Clicks: 124
ID: 185531
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #49 of 50 articles by views in artificial cells, nanomedicine, and biotechnology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background & Objective: In the recent years, nuclear medicine has enjoyed remarkable growth thanks to such novel technologies as SPECT-CT and PET, which are utilized for the recognition of new detectable molecules and radiopharmaceutical medicines. Therefore, the current regulations on radiation protection require revision. Namazi Hospital of Shiraz is one of the first nuclear medicine centers in Iran. Many patients visit this hospital every year; consequently, radiation protection must be screened and evaluated regularly. Radiation protection in the nuclear medicine department has not been assessed in detail yet, so we sought to conduct the first general radiation protection study. Materials & Methods: The radiation dose in each zone was measured and regulated according to the International Commission on Radiological Protection. To this end, measurements were performed over a three-day period, five times a day. Results: The maximum and minimum doses in the nuclear medicine center in Namazi Hospital were 25µSv/h and 0.13µSv/h, respectively. The maximum dose was measured in the SPECT room next to the patient's bed during infusion. The minimum dose was measured behind the SPECT room wall next to the reception. In terms of quality assessment, there are several major environmental problems such as lack of suitable warning signs and sufficient ventilation; however, the main problem is the absence of routine periodical radiation protection studies. Conclusion: The results of these experiments revealed that the radiation protection in the nuclear department of Namazi Hospital met the international standards.
Reference Key
movahedi2013journalevaluation Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Mohammad Mehdi Movahedi;Alireza Mehdizadeh
Journal artificial cells, nanomedicine, and biotechnology
Year 2013
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.