effect of timing of post space preparation on the apical seal when using different sealers and obturation techniques
Clicks: 119
ID: 185001
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
119 views
10 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #48 of 51 articles by views in world academy of science, engineering and technology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Background/purpose: To prepare the post apace, some of the root-canal filling material has to be removed, which can affect the apical seal. The aim of this study was to compare the effect of immediate post space preparation to that of delayed post space preparation on apical sealing using three different endodontic sealers and obturation techniques.
Materials and methods: In total, 90 decrowned single-rooted human teeth were studied. After root canals were prepared with 0.06 tapered nickel–titanium rotary files to size 30, the roots were categorized randomly into three experimental groups according to the obturation material: (1) AH plus/gutta-percha; (2) Sealite Ultra/gutta-percha; and (3) Epiphany/Resilon. Furthermore in all groups, specimens were categorized randomly into three subgroups according to the obturation technique (n = 10): (1) single cone; (2) cold lateral compaction; and (3) System B + Obtura. After root-canal filling, post space preparation was immediately performed in Group 1, after 24 hours in Group 2, and after 7 days in Group 3. Apical leakage was measured using the fluid-filtration method. Statistical analysis was performed using the Kruskal–Wallis test and Wilcoxon signed ranks test at P < 0.001.
Results: Regardless of the obturation technique and sealers used, significantly better (P < 0.001) sealing was achieved at the apical ends using delayed post space preparation than with immediate post preparation. The obturation techniques tested did not significantly affect leakage values. The following statistical ranking of fluid filtration values was obtained for the obturation materials: Epiphany/Resilon > Sealite Ultra/gutta-percha > AH plus/gutta-percha (P < 0.001).
Conclusion: To reduce apical leakage, clinicians should use AH plus together with any of the obturation techniques after 7 days of obturation.
| Reference Key |
nagas2016journaleffect
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Emre Nagas;Elcin Karaduman;Cem Sahin;Ozgur Uyanik;Senay Canay |
| Journal | world academy of science, engineering and technology |