24 h and 30 day outcome of perclose proglide suture mediated vascular closure device: an indian experience

Clicks: 116
ID: 182724
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #389 of 437 articles by views in renewable energy

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 437 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Introduction: Advantages of vascular closure device over manual compression include patient comfort, early mobilisation and discharge, avoidance of interruption of anticoagulation, avoidance of local compression and its sequelae and less time constraint on staff. No published Indian data exist regarding Perclose Proglide suture mediated vascular closure device (SMC). Aim: To study the 24 h and 30 day outcome of Perclose Proglide SMC retrospectively. Study design: Retrospective observational study conducted in the Department of Cardiology, Government Medical College, Calicut, Kerala from June 2013 to June 2015. Methodology: All consecutive patients with Perclose Proglide SMC deployment done by a single operator for achieving access site haemostasis where 24 h and 30 day post-procedure data were available were included. Major and minor complications, procedure success, device failure were predefined. Results: 323 patients were analysed. Procedure success rate was 99.7% (322/323). Transient oozing occurred in 44 patients (13.6%), minor and major complications occurred in 2% and 1.5% of patients respectively. Major complication included one case of retroperitoneal bleed, one access site infection, one pseudo aneurysm formation and two access site arterial stenosis. There was no death or complication requiring limb amputation. “Preclose” technique was used successfully in six patients. Primary device failure occurred in 12 cases which were tackled successfully with second Proglide in all except one. Conclusion: Perclose Proglide SMC is a safe and effective method to achieve haemostasis up to 22F with less complication rate.
Reference Key
vinayakumar2017indian24 h Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Desabandhu Vinayakumar;Shajudeen Kayakkal;Sandeep Rajasekharan;Julian Johny Thottian;Prasanth Sankaran;Cicy Bastian
Journal renewable energy
Year 2017
DOI
10.1016/j.ihj.2016.06.008
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.