preparation of a modified electrode for the determination of levofloxacin

Clicks: 362
ID: 181888
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #4 of 49 articles by views in Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In this study, modification of glassy carbon electrode with electrochemically reduced graphene oxide (ERGO) and acid treated multi-walled carbon nanotubes (A-MWCNT) was investigated for the voltammetric determination of LEV in body fluids and pharmaceutical products. Different combinations of GO, ERGO, MWCNT and A-MWCNT were searched and the best results obtained with GC/ERGO/A-MWCNT electrode. The prepared modified electrode showed electrocatalytic acitivity towards LEV oxidation by increasing oxidation peak currents 293 times. Characterizations of the modified electrode was performed with cyclic voltammetry, electrochemical impedance spectroscopy and raman measurements. The highest oxidation peak current was observed at pH value of 2.0. The oxidation peak currents of LEV increased linearly with the concentration of LEV in the range of 0.01 mM and 10 mM. The detection limit of the prepared sensor was determined as 0.0063 mM. After three weeks’ storage, the prepared electrode showed high stability by preserving 93% of its original activity towards 1.0 mM LEV. The prepared electrode successfully discriminates the voltammetric response of LEV from that of other fluoroquinolone antibiotics (enoxacin, norfloxacin, ciprofloxacin). Finally, the performance of the prepared electrode was tested in the determination of LEV in human blood serum, urine and pharmaceutical samples.
Reference Key
zcan2017anadolupreparation Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Ayça ATILIR ÖZCAN;Mustafa GÜRBÜZ;Ali ÖZCAN
Journal Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir
Year 2017
DOI
10.18038/aubtda.319445
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.