Measurement of the tripeptides glutathione and ophthalmic acid by gas chromatography-mass spectrometry.

Clicks: 459
ID: 181763
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #5 of 75 articles by views in analytical biochemistry

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Glutathione (GSH, γ-glutamyl-cysteinyl-glycine) is the most abundant intracellular dicarboxylic tripeptide with multiple physiological roles. GSH and its symmetric disulfide GSSG co-exist in biological samples. The GSH-to-GSSG molar ratio is high within cells and low in extracellular compartments. It is widely used as a biomarker of oxidative stress. Here, we report on a novel two-step derivatization procedure which allows for the specific quantitative measurement of GSH by gas chromatography-mass spectrometry (GC-MS) in the electron-capture negative-ion chemical ionization mode. The method is based on the derivatization of GSH first with pentafluoropropionic anhydride in ethyl acetate (30 min, 65 °C) and subsequently with 2 M HCl/CHOH (30 min, 80 °C). Esterification in 2 M HCl/CDOD is used for the in situ synthesis of deuterium-labelled GSH for use as internal standard. Quantification is performed by selected-ion monitoring of m/z 557 for GSH and m/z 560 for the internal standard (1 mM). Linear regression analysis between the peak area ratio of m/z 557 to m/z 560 (y) and the GSH concentration (x; range, 0-1 mM) resulted in the regression equations y = 0.02 + 0.62x (r = 0.976) in the absence and y = 0.02 + 0.63x (r = 0.997) in the presence of GSSG (range, 0-1 mM), underlying the linearity of the method for GSH and suggesting lack of interference by GSSG. γ-Glu-Cys and Cys-Gly also did not interfere. The GC-MS method demonstrated that in human hemolysate, nitrite at toxicological concentrations (range, 0-15 mM) depletes erythrocytic GSH. For the GC-MS analysis of the GSH tripeptide analogue ophthalmic acid, which lacks a Cys moiety, the derivatization order was HCl/CHOH followed by pentafluoropropionic anhydride in ethyl acetate.
Reference Key
bollenbach2020measurementanalytical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal analytical biochemistry
Year 2020
DOI
S0003-2697(20)30373-0
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.