efficacy of the methoxyflurane as bridging analgesia during epidural placement in laboring parturient
Clicks: 191
ID: 181526
2015
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
3.3
/100
11 views
11 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
Background: Establishing an epidural in an agitated laboring woman can be challenging. The ideal pain control technique in such a situation should be effective, fast acting, and short lived. We assessed the efficacy of inhalational methoxyflurane (Penthrox™) analgesia as bridging analgesia for epidural placement. Materials and Methods: Sixty-four laboring women who requested epidural analgesia with pain score of ≥7 enrolled in an observational study, 56 of which completed the study. The parturients were instructed to use the device prior to the onset of uterine contraction pain and to stop at the peak of uterine contraction, repeatedly until epidural has been successfully placed. After each (methoxyflurane inhalation-uterine contraction) cycle, pain, Richmond Agitation Sedation Scale (RASS), nausea and vomiting were evaluated. Maternal and fetal hemodynamics and parturient satisfaction were recorded. Results: The mean baseline pain score was 8.2 ± 1.5 which was reduced to 6.2 ± 2.0 after the first inhalation with a mean difference of 2.0 ± 1.1 (95% confidence interval 1.7-2.3, P < 0.0001), and continued to decrease significantly over the study period (P < 0.0001). The RASS scores continuously improved after each cycle (P < 0.0001). Only 1 parturient from the cohort became lightly sedated (RASS = −1). Two parturients vomited, and no significant changes in maternal hemodynamics or fetal heart rate changes were identified during treatment. 67% of the parturients reported very good or excellent satisfaction with treatment. Conclusion: Penthrox™ provides rapid, robust, and satisfactory therapy to control pain and restlessness during epidural placement in laboring parturient.
| Reference Key |
anwari2015saudiefficacy
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Jamil S Anwari;Laith Khalil;Abdullah S Terkawi |
| Journal | bulletin des sociétés chimiques belges |
| Year | 2015 |
| DOI |
10.4103/1658-354X.159457
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.