modified needle drainage. a safe and efficient technique of subretinal fluid drainage in scleral buckling procedure.
Clicks: 408
ID: 180600
2004
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
408 views
40 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #32 of 456 articles by views in Bioinformatics
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 456 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
PURPOSE: To compare modified needle drainage (MND) with conventional drainage (CD) of subretinal fluid (SRF) as described by Schepens in surgery for primary rhegmatogenous retinal detachment. METHODS: Prospective randomised clinical trial of 80 patients undergoing scleral buckling with subretinal fluid drainage for primary rhegmatogenous retinal detachment. In 40 patients modified needle drainage of subretinal fluid (SRF) was done using a perpendicular trans-scleral entry with a 26-gauge needle and the appearance of SRF in the hub of needle as end point. In 40 patients conventional drainage was done as described by Schepens using a diathermy needle. Adequacy of SRF drainage, intraoperative complications, anatomical and functional outcome were noted. RESULTS: 100% adequate drainage was achieved in all cases. The complication rate was 32.5% (n=13) in the CD group and 15% (n=6) in the MND group. In the CD group, 17.5% (n=7) patients had subretinal haemorrhage and in 2 eyes it was clinically significant. In the MND group 15% (n=6) of cases had subretinal haemorrhage and in one patient it was clinically significant. In the CD group, more serious SRF drainage complications were observed; these were absent in the MND group. CONCLUSION: Modified needle drainage is a safe and effective procedure for SRF drainage. In comparison with CD, MND is technically easy, less cumbersome and requires no special equipment.
| Reference Key |
rajvardhan2004indianmodified
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Azad Rajvardhan;Kumar Ashok;Sharma Yog;Rajpal |
| Journal | Bioinformatics |
| Year | 2004 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments