numerical study of separated flows control in the intermediate turbine diffusers via synthetic jets

Clicks: 153
ID: 179293
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #414 of 442 articles by views in BMJ open

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 442 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The paper studies turbulent separation flows in the intermediate turbine diffusers and their control via synthetic jets using a combined high-resolution RANS/ILES method (Reynolds Averaged Navier-Stokes - RANS, Implicit Large Eddy Simulation - ILES). Calculations were performed for two variants of S-shaped diffusers geometry: standard and "aggressive" (20% shorter than standard) on the grids containing 0.88×106 cells. The paper also considers flow modes in diffusers for several values of pressure difference. The effect of diffusers geometry on their flow parameters in them was defined. The effect of synthetic jets on the flow separation and characteristics of flow and turbulence was considered. A parametric study was conducted to define the influence of synthetic jet amplitude and frequency on the flow. Synthetic jets are generated by periodic gas blowing and suction through the slots of the cavity with a movable diaphragm - a generator of synthetic jets. They do not require special working gas and means for its supply are compact and efficient. For studied modes, the levels of total pressure losses and turbulent fluctuations at the diffusers output, as well as distribution of the averaged flow parameters were shown. The flow parameters in the standard and the "aggressive" diffusers both with jets and with no jets in the same mode were compared. It was found that using the synthetic jets in considered diffusers allows us to improve their characteristics and in case of "aggressive" diffuser approximate them closer to the level of the standard.
Reference Key
potekhina2015naukanumerical Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;I. V. Potekhina;D. A. Lyubimov
Journal BMJ open
Year 2015
DOI
10.7463/0115.0753472
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.