cardiac pacemaker battery discharge after external electrical cardioversion for broad qrs complex tachycardia
Clicks: 203
ID: 178596
2008
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
203 views
28 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #27 of 63 articles by views in Medical decision making : an international journal of the Society for Medical Decision Making
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
External electrical cardioversion or defibrillation may be necessary in patients with implanted cardiac pacemaker (PM) or implantable cardioverter defibrillator (ICD). Sudden discharge of high electrical energy employed in direct current (DC) transthoracic countershock may damage the PM/ICD system resulting in a series of possible device malfunctions. For this reason, when defibrillation or cardioversion must be attempted in a patient with a PM or ICD, some precautions should be taken, particularly in PM dependent patients, in order to prevent damage to the device. We report the case of a 76-year-old woman with a dual chamber PM implanted in the right subclavicular region, who received two consecutive transthoracic DC shocks to treat haemodynamically unstable broad QRS complex tachycardia after cardiac surgery performed with a standard sternotomic approach. Because of the sternal wound and thoracic drainage tubes together with the severe clinical conditions, the anterior paddle was positioned near the pulse generator. At the following PM test, a complete flat battery was detected.
| Reference Key |
roberto2008indiancardiac
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Zamparelli Roberto;Dello Russo Antonio;Pelargonio Gemma;Martino Annamaria;Sanna Tommaso;Casella Michela;Scapigliati Andrea;De Paulis Stefano;Bellocci Fulvio;Schiavello Rocco |
| Journal | Medical decision making : an international journal of the Society for Medical Decision Making |
| Year | 2008 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.