airborne microorganism disinfection by photocatalytic hepa filter
Clicks: 178
ID: 177416
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
178 views
16 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #16 of 23 articles by views in the aging male : the official journal of the international society for the study of the aging male
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This study determined the efficacy of photocatalytic HEPA filters on microorganism disinfection in a closed-loop chamber and later applied it in an air purifier and tested its efficacy in an 8-m3 chamber and in a hospital. The photocatalytic filters were made by dip-coating a HEPA filter in a TiO2 slurry. In order to disinfect the microorganisms retained on the filter, UV-A light was irradiated onto the filter to create strong oxidative radicals which can destroy microorganisms. The findings showed that disinfection efficiency of the photocatalytic filters with high TiO2 loading was insignificantly higher than with lower loading. S. epidermidis was completely eliminated within 2 hours, while 86.8% of B. subtilis, 77.1% of A. niger, and 82.7% of P. citrinum were destroyed within 10 hours. When applying the photocatalytic filters into an air purifier in a 8-m3 chamber, it was found that as soon as the air purifier was turned on, 83.4% of S. epidermidis, 81.4% of B. subtilis, 88.5% of A. niger, and 75.8% of P. citrinum were removed from the air. In a hospital environment, the PCO air purifier efficacy was lower than that in the chamber. Besides, relative humidity, distances from the air purifier and room size were suspected to affect the efficacy of the photocatalytic filters.
| Reference Key |
chotigawin2010environmentasiaairborne
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Rotruedee Chotigawin;Paradee Chuaybamroong |
| Journal | the aging male : the official journal of the international society for the study of the aging male |
| Year | 2010 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.