automatic pressure stabilization in front of the evaporators in the multifunctional heat pump
Clicks: 208
ID: 176635
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
208 views
26 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #23 of 36 articles by views in indonesian journal of electrical engineering and computer science
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The aim of the article is to elaborate and to investigate the automatic control system of pressure in front of evaporators of the multifunctional heat pump, which has several condensers and several evaporators. The control system must reduce the value of pressure perturbations acting on evaporators and decrease the value of pressure pulsations before them. To solve this problem, a hydraulic scheme has been developed in which this parameter is stabilized by using fine and coarse adjustment valves in hydraulic circuits of condensers and compressors using a pressure control system for a static flow mixer. The system for control of the flow of the refrigerant consists of two groups of compressors with automatic control drives installed in the lines of each of the condensers. The pressure control system uses a model of control valve with proportional-integral – derivative (PID) controller in the direct line of the controller loop. This solution allowed simplifying the heat pump control system by eliminating the necessity of matching the pressure and flow control valves in each line and controlling the flow in the line over a wider range as well. A mathematical model of the static mixer of flows installed after the pressure control valves is obtained. The proposed pressure control system gives a possibility to reduce the amplitude of pulsations of pressure before the evaporators up to 14-16 times.
| Reference Key |
m.l.2017problemsautomatic
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Sit M.L.;Zhuravleov A.A. |
| Journal | indonesian journal of electrical engineering and computer science |
| Year | 2017 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org