a new non-invasive device to monitor core temperature on earth and in space
Clicks: 84
ID: 176363
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
24.3
/100
84 views
11 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #12 of 16 articles by views in zhidkie kristally i ikh prakticheskoe ispol'zovanie
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Accurate measurement of the core body temperature (cbt) is fundamental to the study of human temperature regulation. As standard sites for the placement of cbt measurement sensors have been used: the rectum, the bladder, the esophagus, the nasopharynx and the acoustic meatus. Nevertheless those measurement sites exhibit limited applicability under field conditions, in rescue operations or during peri- and postoperative long-term core temperature monitoring. There is, indeed, a high demand for a reliable, non-invasive, easy to handle telemetric device. But the ideal non-invasive measurement of core temperature has to meet requirements such as i) a convenient measurement site, ii) no bias through environmental conditions, and iii) a high sensitivity of the sensor regarding time shift and absolute temperature value. Recently, together with the Draegerwerke AG we have developed a new heat flux measurement device (so-called "Double Sensor") as a non-invasive cbt sensor aiming to meet the requirements described above. Four recent studies in humans will be summarized and discussed to show the applicability of this new non-invasive method to monitor core temperature under different environmental and clinical settings on Earth and in space.
| Reference Key |
gunga2012annalesa
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Hanns-Christian Gunga;Andreas Werner;Oliver Opatz;Alexander Stahn;Karl Kirsch;Frank Sattler;Jochim Koch |
| Journal | zhidkie kristally i ikh prakticheskoe ispol'zovanie |
| Year | 2012 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.