ecocardiografia e teste de caminhada de 6 minutos na disfunção sistólica do ventrículo esquerdo ecocardiografía y prueba de caminata de 6 minutos en la disfunción sistólica del ventrículo izquierdo chocardiography and 6-minute walk test in left ventricular systolic dysfunction
Article Quality & Performance Metrics
Readership in this journal
SteadyRanked #38 of 230 articles by views in revista cubana de ciencias informáticas
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 230 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
FUNDAMENTO: La insuficiencia cardiaca crónica es un grave disturbio cardiovascular. OBJETIVO: El objetivo de este estudio fue evaluar prospectivamente si el resultado de la prueba de caminata de 6 minutos (PC-6M) se correlaciona con las variables ecocardiográficas en pacientes portadores de disfunción sistólica del ventrículo izquierdo e insuficiencia cardiaca crónica estable. MÉTODOS: Se estudiaron prospectivamente a 52 pacientes (el 65% varones; promedio de edad de 60±11 años) portadores de insuficiencia cardiaca crónica secundaria a la cardiopatía isquémica o la miocardiopatía idiopática. Todos los pacientes presentaban disfunción sistólica del ventrículo izquierdo (fracción de eyección <0.45) y se encontraban en insuficiencia cardiaca clase funcional II ó III de la NYHA. Se realizaron un estudio de Ecocardiografía Doppler y una PC-6M en el mismo día. RESULTADOS: La PC-6M presentó correlación moderada, pero estadísticamente significante, con el diámetro sistólico final (DSF): r=-0,46; p=0,0006; con la fracción de acortamiento (FA): r=0,52; p=0,0001; y con la fracción de eyección (FE): r=0,5; p=0,0001. Presentó también correlación débil, pero estadísticamente significante, con el índice de desempeño miocárdico (IDM): r=-0,39; p=0,0046; la relación E/A (tricúspide): r=-0,333; p=0,016; el tiempo de aceleración del flujo pulmonar: r=0,328; p=0,018; y con la amplitud del eje largo lateral: r=0,283; p=0,04. El modelo de regresión lineal evidenció que la edad (χ2=-0,59, p=<0,001), el patrón de llenado restrictivo transmitral (χ2=-0,44, p=0,004) y la dimensión sistólica final del ventrículo izquierdo (χ2=-0,34, p=0,012) fueron factores independientes que influencian la PC-6M. CONCLUSIONES: En pacientes portadores de insuficiencia cardiaca resultante de disfunción sistólica del ventrículo izquierdo, la PC-6M como herramienta de evaluación clínica de la capacidad funcional presenta una correlación significante con los principales parámetros de la función sistólica global del VI y con el IDM del VI. En pacientes con disfunción sistólica del VI, la edad, el patrón de llenado restrictivo transmitral y la dimensión sistólica del ventrículo izquierdo se mostraron independientemente asociados a la PC-6M.
BACKGROUND: Chronic heart failure is a major cardiovascular disorder. OBJECTIVE: The aim of this study was to prospectively examine whether a 6-min walk test (6-MWT) result correlates with echocardiographic variables in patients with left ventricular systolic dysfunction and stable chronic heart failure. METHODS: We prospectively studied 52 patients (65% male; mean age 60±11 years) who had chronic heart failure secondary to ischemic heart disease or idiopathic cardiomyopathy. All patients had left ventricular systolic dysfunction (ejection fraction <0.45), and were in stable NYHA class II or III heart failure. An echo-Doppler study and a 6-MWT were performed on the same day. RESULTS: 6-MWT had moderate, but statistically significant correlation with end-systolic diameter (ESD) (r=-0.46; p=0.0006), with shortening fraction-SF (r=0.52; p=0.0001), and with ejection fraction-EF (r=0.5; p=0.0001), whereas it had poor, but statistically significant correlation with myocardial performance index-MPI (r=-0.39; p=0.0046), E/A(tricuspid) ratio (r=-0.333; p=0.016), pulmonary acceleration time (r=0.328; p=0.018), and lateral long axis amplitude (r=0.283; p=0.04). Linear regression model demonstrated that age (χ2=-0.59, p=<0.001), restrictive transmitral filling pattern (χ2=-0.44, p=0.004) and left ventricular end-systolic dimension (χ2=-0.34, p=0.012) were independent factors that influenced the 6-MWT. CONCLUSION: In patients with heart failure due to left ventricular systolic dysfunction, the 6-MWT as a clinical assessment tool of the functional capacity has a significant correlation with the most important global LV systolic function parameters, as well as with LV MPI. In patients with LV systolic dysfunction, age, restrictive transmitral filling pattern, and left ventricular systolic dimension, were independently associated with the 6-MWT.
| Reference Key |
berisha2009arquivosecocardiografia
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Venera Berisha;Gani Bajraktari;Dritero Dobra;Edmond Haliti;Reshat Bajrami;Shpend Elezi |
| Journal | revista cubana de ciencias informáticas |
| Year | 2009 |
| DOI |
10.1590/S0066-782X2009000200009
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.