assessment of the effect of water deficit on sap flow of longkong trees by using heat-pulse method
Клики: 178
ID: 172054
2002
Метрики качества и эффективности статьи
Общее качество
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Вовлечённость читателей
Popular Article
30.0
/100
178 просмотры
26 читатели
Оценка качества ИИ
Не проанализировано
Readership in this journal
PopularRanked #72 of 95 articles by views in ferroelectrics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Аннотация
The effect of water deficit on sap flow of longkong trees was studied by using heat-pulse method. An experiment was carried out in a glasshouse over 30-day period. There were 3 treatments: 1) daily watering or control, 2) 5-day interval watering or moderate water deficit (MWD) and 3) 10-day interval watering or high water deficit (HWD) with 4 replications. Twelve longkong trees (3-year old) were used. Each tree was grown in a 30L polybag filled with soil mixture. It was found that leaf water potential, stomatal conductance and Fv/Fm (at 10 day interval) in the MWD and HWD continuously decreased through the experimental period, and they were significantly different from those of the control at the end of the experimental period. Sap flow in the MWD and HWD treatments were consistently low around day 16 and day 13 after starting the experiment. Concomitantly, stomatal conductance of HWD rapidly decreased from day 10, and it was significantly different from those in MWD and control treatments. This implies that water deficit caused stomatal closure leading to the reduction of transpiration. Hence, it appears that water deficit causes the decrease of sap flow in longkong tree, and this incidence depends on the severity of water deficit.
| Ссылочный ключ |
sdoodee2002songklanakarinassessment
Используйте этот ключ для автоцитирования в рукописи при использовании
SciMatic Manuscript Manager или Thesis Manager
|
|---|---|
| Авторы | ;Sayan Sdoodee;Naree Wongwongaree |
| Журнал | ferroelectrics |
| Год | 2002 |
| DOI |
DOI не найден
|
| URL | |
| Ключевые слова |
Цитирования
Цитирования не найдены. Чтобы добавить цитирование, свяжитесь с администратором по адресу info@scimatic.org
Комментарии
Комментариев пока нет. Будьте первым, кто прокомментирует эту статью.