solution of the problem of pipes freezing with account for external heat exchange

Clicks: 212
ID: 171329
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #55 of 140 articles by views in PsyCh journal

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 140 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The author considered the problem statement on the pipes freezing in emergency regimes of building engineering systems and external pipe nets using liquid water as working fluid under boundary conditions of the 3rd type. This problem is a high-priority task now because of actualization of building standards in Russian Federation and because of the increasing requirements to safety and security of heat supply. That’s why it is very important to find a simple but accurate enough dependence for the freezing time in pipe nets. The system of differential and algebraic equations of external heat exchange and internal heat transfer with account for heat ingress from hydraulic friction at water flow and Stephan’s condition on the freezing front is presented. The analytical solution of the given system is obtained as a quadrature for the dependence of the current coordinate of the freezing front. The results of numerical calculation of the corresponding integral are shown and their comparison with the former author’s researches concerning the solution of the considered problem at the boundary conditions of the 1st type is conducted. It is shown that the account of intensity of external heat exchange causes retarding of freezing because of adding thermal resistance on the external surface of the pipe. The former author’s conclusion on the existence of the ultimate water velocity, when freezing doesn’t take place, is verified. The area of use of the presented dependence is found. The obtained model contains is easy to use in engineering practice, especially during preliminary calculations. The presentation is illustrated with numerical and graphical examples.
Reference Key
dmitrievich2015vestniksolution Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Samarin Oleg Dmitrievich
Journal PsyCh journal
Year 2015
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.