detection of lymph node involvement in hematologic malignancies using micromagnetic resonance lymphangiography with a gadolinum-labeled dendrimer nanoparticle

Clicks: 293
ID: 170372
2005
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #38 of 203 articles by views in ACS chemical neuroscience

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 203 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Animal models of lymphoma should reflect their counterparts in humans; however, it can be difficult to ascertain whether an induced disease is intralymphatic or extralymphatic based on direct visualization. Current imaging methods are insufficient for identifying lymphatic and intralymphatic involvement. To differentiate intralymphatic from extralymphatic involvement, we have developed a magnetic resonance imaging-based lymphangiography method and tested it on two animal models of lymphoma. A gadolinium (Gd)-labeled dendrimer nanoparticle (generation-6; ~220 kDa/f10 nm) was injected interstitially into mice bearing hematologic malignancies to perform dynamic micromagnetic resonance lymphangiography (micro-MRL). Both a standard T1-weighted 3D fast spoiled gradient echo and a T2/T1-weighted 3D fast imaging employing steady-state acquisition (3D-FIESTA-C) were compared in an imaging study to differentiate intralymphatic from extralymphatic involvement of tumors. The lymphatics and lymph nodes were visualized with both methods in all cases. In addition, 3D-FIESTA-C depicted both the lymphatic system and the extralymphatic tumor. In an animal model, 3D-FIESTA-C demonstrated that the bulk of the tumor thought to be intralymphatic was actually extralymphatic. In conclusion, micro-MRL, using Gd-labeled dendrimer nanoparticles with the combined method, can define both the normal and abnormal lymphatics and can distinguish intralymphatic from extralymphatic diseases in mouse models of malignant lymphoma.
Reference Key
kobayashi2005neoplasia:detection Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Hisataka Kobayashi;Satomi Kawamoto;Martin W. Brechbiel;Marcelino Bernardo;Noriko Sato;Thomas A. Waldmann;Yutaka Tagaya;Peter L. Choyke
Journal ACS chemical neuroscience
Year 2005
DOI
10.1593/neo.05454
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.