the effect of exercising with manual compression foot pumps, on dialysis efficiency, in patients with end stage renal disease
Clicks: 211
ID: 168167
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
211 views
38 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #31 of 48 articles by views in international journal of rotating machinery
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Aim: This study aimed to establish if exercising with manual compressionfoot-pumps, could be used as an intervention to improve dialysis efficacy. A pre test -post test design was used to test the intervention. Subjects were invited to participate in the study depending on whether they fitted the eligibility criteria of the study. Eight weeks after entry into the study pre-test values of dialysis efficacy (Kt/V ) were established prior to the implementation of an eight-week exercise programme followed by the collection of post intervention dialysis efficacy values. Subjects performed seated heel raises with manual compression foot-pumps on their feet (Venous A nti-stasis Slippers) for 20 continuous minutes per hour for the first three hours of their dialysis sessions (two or three times per week). Twelve subjects finished the programme. During the eight weeks of exercise an increaseof 8.7% was noted in Kt/V values with a mean change of 0.12 (p=0.04). It appears that an eight week exercise programme using manual compression foot pumps (Venous A nti-stasis Slippers) may be effective in improving dialysisefficiency. These findings need to be tested in a study with an appropriate sample size.
| Reference Key |
kern2009souththe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;J. Kern;A. Stewart;P. Becker |
| Journal | international journal of rotating machinery |
| Year | 2009 |
| DOI |
10.4102/sajp.v65i2.80
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.