measurement of t1 of the ultrashort t2* components in white matter of the brain at 3t.
Clicks: 104
ID: 167552
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
104 views
23 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #215 of 234 articles by views in ensaio pesquisa em educação em ciências
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 234 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Recent research demonstrates that white matter of the brain contains not only long T2 components, but a minority of ultrashort T2* components. Adiabatic inversion recovery prepared dual echo ultrashort echo time (IR-dUTE) sequences can be used to selectively image the ultrashort T2* components in white matter of the brain using a clinical whole body scanner. The T2*s of the ultrashort T2* components can be quantified using mono-exponential decay fitting of the IR-dUTE signal at a series of different TEs. However, accurate T1 measurement of the ultrashort T2* components is technically challenging. Efficient suppression of the signal from the majority of long T2 components is essential for robust T1 measurement. In this paper we describe a novel approach to this problem based on the use of IR-dUTE data acquisitions with different TR and TI combinations to selectively detect the signal recovery of the ultrashort T2* components. Exponential recovery curve fitting provides efficient T1 estimation, with minimized contamination from the majority of long T2 components. A rubber phantom and a piece of bovine cortical bone were used for validation of this approach. Six healthy volunteers were studied. An averaged T2* of 0.32 ± 0.09 ms, and a short mean T1 of 226 ± 46 ms were demonstrated for the healthy volunteers at 3T.
| Reference Key |
du2014plosmeasurement
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Jiang Du;Vipul Sheth;Qun He;Michael Carl;Jun Chen;Jody Corey-Bloom;Graeme M Bydder |
| Journal | ensaio pesquisa em educação em ciências |
| Year | 2014 |
| DOI |
10.1371/journal.pone.0103296
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.