devices for accurate placement of epidural tuohy needle for anaesthesia administration

Clicks: 128
ID: 167445
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #23 of 31 articles by views in advances in medical education and practice

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The aim of this project is to design two sterile devices for epidural needle insertion which can measure in real time (i) the depth of needle tip during insertion and (ii) interspinous pressure changes through a pressure measurement device as the epidural needle is advanced through the tissue layers. The length measurement device uses a small wireless camera with video processing computer algorithms which can detect and measure the moving needle. The pressure measurement device uses entirely sterile componenets including a pressure transducer to accurately measure syringe saline in mm Hg. The data from these two devices accurately describe a needle insertion allowing comparison or review of insertions. The data was then cross-referenced to pre-measured data from MRI or ultrasound scan to identify how ligemant thickness correlates to our measured depth and pressure data. The developed devices have been tested on a porcine specimen during insertions performed by experienced anaesthetists. We have obtained epidural pressures for each ligament and demonstrated functionality of our devices to measure pressure and depth of epidural needle during insertion. This has not previously been possible to monitor in real-time. The benefits of these devices are (i) to provide an alternative method to identify correct needle placement during the procedure on real patients. (ii) The data describing the speed, depth and pressure during insertion can be used to configure an epidural simulator, simulating the needle insertion procedure. (iii) Our pressure and depth data can be compared to pre-measured MRI and ultrasound to identify previously unknown links between epidural pressure and depth with BMI, obesity and body shapes.
Reference Key
vaughan2014mechanicaldevices Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;N. Vaughan;V. N. Dubey;M. Y. K. Wee;R. Isaacs
Journal advances in medical education and practice
Year 2014
DOI
10.5194/ms-5-1-2014
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.