devices for accurate placement of epidural tuohy needle for anaesthesia administration
Clicks: 128
ID: 167445
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
128 views
33 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #23 of 31 articles by views in advances in medical education and practice
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The aim of this project is to design two sterile devices for epidural needle
insertion which can measure in real time (i) the depth of needle tip during
insertion and (ii) interspinous pressure changes through a pressure
measurement device as the epidural needle is advanced through the tissue
layers. The length measurement device uses a small wireless camera with
video processing computer algorithms which can detect and measure the moving
needle. The pressure measurement device uses entirely sterile componenets
including a pressure transducer to accurately measure syringe saline in
mm Hg. The data from these two devices accurately describe a needle insertion
allowing comparison or review of insertions. The data was then
cross-referenced to pre-measured data from MRI or ultrasound scan to
identify how ligemant thickness correlates to our measured depth and
pressure data. The developed devices have been tested on a porcine specimen
during insertions performed by experienced anaesthetists. We have obtained
epidural pressures for each ligament and demonstrated functionality of our
devices to measure pressure and depth of epidural needle during insertion.
This has not previously been possible to monitor in real-time. The benefits
of these devices are (i) to provide an alternative method to identify
correct needle placement during the procedure on real patients. (ii) The
data describing the speed, depth and pressure during insertion can be used
to configure an epidural simulator, simulating the needle insertion
procedure. (iii) Our pressure and depth data can be compared to pre-measured
MRI and ultrasound to identify previously unknown links between epidural
pressure and depth with BMI, obesity and body shapes.
| Reference Key |
vaughan2014mechanicaldevices
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;N. Vaughan;V. N. Dubey;M. Y. K. Wee;R. Isaacs |
| Journal | advances in medical education and practice |
| Year | 2014 |
| DOI |
10.5194/ms-5-1-2014
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.