an in vitro study to evaluate the effect of storage time and application of subsequent layers on the variation in thickness of three commercially available die spacers
Clicks: 156
ID: 167084
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
156 views
15 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #120 of 150 articles by views in Applied and environmental microbiology
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 150 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Aims : The application of a paint-on die spacer onto the dies prior to the fabrication of cast crowns is an acceptable procedure to improve the fit of the restoration. The primary purpose of this study was to evaluate the variation in thickness of different brands of die spacer based on the effect of storage time and application of additional layers. Materials and Methods: Dies were duplicated from a master model of ivorine teeth, with a full ceramic preparation. Dies obtained were then painted with one, two, and three coats of each brand of die-spacers separately. These dies were embedded in die stone and sectioned bucco-lingually. The same procedure was done after three and six months. The thickness of the paint on die spacer was measured at five points on the die using an optical microscope, and the data were statistically analyzed. Results and Conclusion : There was a definite variation in the thickness of the die spacer with all the three brands and at various points on the die. Two coat thicknesses were found to be in the range of tolerance of 20-40 microns. Thickness at occlusal groove was noted to be the maximum with least at occlusoaxial line angles. Thickness also showed a very significant increase when bottles were stored for a period of three to six months and then applied.
| Reference Key |
sunil2010indianan
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Jacob Sunil;Hegde Chethan;Prasad Krishna;Shetty Manoj |
| Journal | Applied and environmental microbiology |
| Year | 2010 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.