opção técnica na tetralogia de fallot com artéria coronária anômala: relato de casos technical option on tetralogy of fallot with abnormal coronary artery: cases report
Clicks: 268
ID: 166274
2008
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
268 views
31 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #29 of 103 articles by views in 2017 international conference on information technology systems and innovation, icitsi 2017 - proceedings
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Relatamos dois casos um menino de 11 anos e uma menina de um ano e seis meses, portadores de tetralogia de Fallot com artéria coronária de origem anômala, cruzando a via de saída de ventrículo direito. O diagnóstico foi feito com ecocardiografia e cateterismo cardíaco. Utilizamos, na correção, um enxerto externo composto de pericárdio bovino e parede posterior da artéria pulmonar, entre o ventrículo direito e o tronco da artéria pulmonar. As crianças tiveram boa evolução pós-operatória, obtendo alta hospitalarassintomáticas. É mais uma opção técnica na correção da tetralogia de Fallot com artéria coronária anômala.
Report on two children, one 11 year-male and another one year-six-month-female with tetralogy of Fallot associated with anomalous origin of coronary artery crossing the right ventricle outlet tract. Diagnosis was done by echocardiography and cardiac catheterization. On surgical correction we used an external composite tubular pericardium bovine graft and posterior wall of the pulmonary artery between the right ventricle and the pulmonary artery trunk. Patients had an uneventful post-operative period and were discharged asymptomatic. It is more an option on correction of tetralogy of Fallot with anomalous coronary artery.
Report on two children, one 11 year-male and another one year-six-month-female with tetralogy of Fallot associated with anomalous origin of coronary artery crossing the right ventricle outlet tract. Diagnosis was done by echocardiography and cardiac catheterization. On surgical correction we used an external composite tubular pericardium bovine graft and posterior wall of the pulmonary artery between the right ventricle and the pulmonary artery trunk. Patients had an uneventful post-operative period and were discharged asymptomatic. It is more an option on correction of tetralogy of Fallot with anomalous coronary artery.
| Reference Key |
assumpo2008brazilianopo
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Claudio Roberto Assumpção;João de Deus e Brito;Eulália Pfeifer;Lilian Stewart;Antonio de Pádua Jazbik |
| Journal | 2017 international conference on information technology systems and innovation, icitsi 2017 - proceedings |
| Year | 2008 |
| DOI |
10.1590/S0102-76382008000200019
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.