attenuation of peak sound pressure levels of shooting noise by hearing protective earmuffs
Clicks: 235
ID: 164920
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
235 views
67 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #21 of 26 articles by views in the cochrane library
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Transmission losses (TL) to highly impulsive signals generated by three firearms have been measured for two ear muffs, using both a head and torso simulator and a miniature microphone located at the ear canal entrance (MIRE technique). Peak SPL TL have been found to be well approximated by 40 ms short-L eq TL. This has allowed the use of transmissibilities and correction factors for bone conduction and physiological masking appropriate for continuous noise, for the calculation of REAT-type peak insertion losses (IL). Results indicate that peak IL can be well predicted by estimates based on one-third octave band 40 ms short L eq and manufacturer-declared (nominal) IL measured for continuous noise according to test standards. Such predictions tend to be more accurate at the high end of the range, while they are less reliable when the attenuation is lower. A user-friendly simplified prediction algorithm has also been developed, which only requires nominal IL and one-third octave sound exposure level spectra. Separate predictions are possible for IL in direct and diffuse sound fields, albeit with higher uncertainties, due to the smaller number of experimental data comprising the two separate datasets on which such predictions are based.
| Reference Key |
lenzuni2012noiseattenuation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Paolo Lenzuni;Tommaso Sangiorgi;Luigi Cerini |
| Journal | the cochrane library |
| Year | 2012 |
| DOI |
10.4103/1463-1741.97246
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.