radiation optic neuropathy and retinopathy with low dose (20 gy) radiation treatment

Clicks: 172
ID: 163890
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #41 of 58 articles by views in contemporary clinical trials communications

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Purpose: To report a case of optic neuropathy and retinopathy from a dose of radiation traditionally thought to be safe to the visual system and discuss strategies for preventing vision loss when using radiation to treat intraocular tumors. Observations: A 44-year-old woman presented with new, painless vision loss in the left eye eighteen months after receiving proton beam radiotherapy (20 Gy dose delivered in two 10 Gy fractions) for a uveal metastasis of lung cancer. The dilated funduscopic examination revealed optic disc swelling and retinal hemorrhages and an MRI of the brain and orbits demonstrated enhancement of the left optic nerve head, findings consistent with radiation optic neuropathy (RON) and retinopathy. Risk factors for developing RON included coincident use of oral chemotherapy and relatively large fractionated doses of radiation. Conclusions and importance: Though cumulative radiation doses to the anterior visual pathway of less than 50 Gy are traditionally felt to be safe, it is important to consider not just the total exposure but also the size of individual fractions. The single-dose threshold for RON in proton beam treatment has yet to be defined. Our case suggests that fractions of less than 10 Gy should be delivered to minimize the risk of optic nerve injury.
Reference Key
peeler2016americanradiation Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Crandall E. Peeler;Dean M. Cestari
Journal contemporary clinical trials communications
Year 2016
DOI
10.1016/j.ajoc.2016.06.008
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.