microchannels effective method for the extraction of oleuropein compared with conventional methods

Clicks: 108
ID: 163410
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #170 of 215 articles by views in british journal of psychology (london, england : 1953)

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 215 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Different methods of oleuropein extraction from olive leaf were investigated, including maceration, soxhlet, ultrasonic-assisted extraction, and microchannel. In current research, a response surface methodology (RSM) was used for prediction of the optimal values of parameters affecting the extraction of oleuropein through two methods of ultrasound and microchannel. Frequency (F), temperature (T), and power of ultrasound (P) were the parameters which were studied in ultrasound method, but in microchannel system effects of pH and temperature (T), volumetric flow rate ratio of two phases (VR), and contact time (CT) of two phases were optimized. UV detector device at 254 nm was used to recognize oleuropein through comparison of the retention time of the extracts with standard compound in chromatogram. The analysis of extracts was performed using HPLC. Optimum conditions for ultrasound were obtained as follows: F=80 kHz, T = 25°C, and P=100 w. Using these optimum conditions, the extraction of oleuropein was 81.29%. Amount of oleuropein extraction by microchannel method in optimum conditions was 96.29%, which was way more than other applied methods. Microchannel system as a continuous method has many advantages including low solvent consumption, being environment friendly, short time for extraction, and high efficiency.
Reference Key
yasemi2017journalmicrochannels Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Mahnaz Yasemi;Amir Heydarinasab;Masoud Rahimi;Mehdi Ardjmand
Journal british journal of psychology (london, england : 1953)
Year 2017
DOI
10.1155/2017/6594156
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.