fault diagnosis and detection in industrial motor network environment using knowledge-level modelling technique
Clicks: 225
ID: 163234
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
225 views
56 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #28 of 66 articles by views in Food science & nutrition
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this paper, broken rotor bar (BRB) fault is investigated by utilizing the Motor Current Signature Analysis (MCSA) method. In industrial environment, induction motor is very symmetrical, and it may have obvious electrical signal components at different fault frequencies due to their manufacturing errors, inappropriate motor installation, and other influencing factors. The misalignment experiments revealed that improper motor installation could lead to an unexpected frequency peak, which will affect the motor fault diagnosis process. Furthermore, manufacturing and operating noisy environment could also disturb the motor fault diagnosis process. This paper presents efficient supervised Artificial Neural Network (ANN) learning technique that is able to identify fault type when situation of diagnosis is uncertain. Significant features are taken out from the electric current which are based on the different frequency points and associated amplitude values with fault type. The simulation results showed that the proposed technique was able to diagnose the target fault type. The ANN architecture worked well with selecting of significant number of feature data sets. It seemed that, to the results, accuracy in fault detection with features vector has been achieved through classification performance and confusion error percentage is acceptable between healthy and faulty condition of motor.
| Reference Key |
altaf2017modellingfault
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Saud Altaf;Muhammad Waseem Soomro;Mirza Sajid Mehmood |
| Journal | Food science & nutrition |
| Year | 2017 |
| DOI |
10.1155/2017/1292190
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.