impact of rna integrity and blood sample storage conditions on the gene expression analysis
Clicks: 348
ID: 162336
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
348 views
47 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #14 of 171 articles by views in jurnal tam
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 171 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Yanting Shen,1,2 Rui Li,1 Fei Tian,1 Zhenzhu Chen,1 Na Lu,2 Yunfei Bai,2 Qinyu Ge,2 Zuhong Lu1,2 1School of Biomedical Engineering, Southeast University, Nanjing 210096, Jiangsu Province, People’s Republic of China; 2State Key Laboratory of Bioelectronics, Southeast University, Nanjing 210096, Jiangsu Province, People’s Republic of China Background: The reliability of RNA sequencing (RNA-seq) output is affected by the quality of RNAs, which is in turn dependent on the quality of samples. Therefore, the purposes of this study were to reconsider the threshold of the RNA integrity number (RIN) and propose a simple and efficient storage scheme of blood samples for RNA-seq.Patients and methods: The RNAs were extracted from blood samples that were stored at different conditions and used for sequencing. The bioinformatic analyses were performed to evaluate the impact of RNA integrity and blood sample storage conditions on the gene expression analysis.Results: Our outcomes showed that the samples with RIN values more than 5.3 scarcely affected the quantitative results of RNA-seq, and the influence of inherent cellular physiological processes on RNA-seq output could be negligible.Conclusion: The blood samples stored at 4°C within 7 days with RIN values more than 5.3 were available for RNA-seq. Keywords: RNA, NGS, blood, integrity, RIN, sequencing
| Reference Key |
yt2018oncotargetsimpact
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Shen YT;Li R;Tian F;Chen ZZ;Lu N;Bai YF;Ge QY;Lu ZH |
| Journal | jurnal tam |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.