measurement of consumption of sevoflurane for short pediatric anesthetic procedures: comparison between dion′s method and dragger algorithm

Clicks: 142
ID: 161389
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #62 of 80 articles by views in molecular ecology resources

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: The most common drugs used in an operating room are the "Inhalation agents" for maintenance of anesthesia yet their measurement methods during the procedure are not well-validated. Conventional methods of measuring the vaporizer weight after each use suffers from practical limitations of high error and time constraints. Aims: We compared two alternative methods available (Dion′s method and Drager Inc. patent protocol) for their degree of concordance and correlation in real-time consumption of sevoflurane for pediatric procedures. Methodology: One hundred pediatric patients scheduled for ophthalmological examination under anesthesia were included in the study. Anesthesia was induced and maintained using sevoflurane with oxygen and nitrous oxide (1:1) on Primus workstation (Drager Inc., Germany). Total sevoflurane consumed for each procedure was calculated using Dion′s equation and the values obtained from Drager Primus were noted and compared. Results: Both methods showed a very strong correlation (0.895 [P < 0.001]). Dion′s method underestimated consumption by 2.59 ml with limits of agreement between 5.188 ml and −0.008 ml. Both test results showed a strong correlation, but poor concordance. Conclusions: Dion′s method strongly correlates with Drager protocol although concordance between the two methods for measuring anesthetic gas consumption is poor. Dion′s method underestimates the consumption and with slight modification addressing this underestimation, it can be electronically incorporated in other workstations to overcome limitations of real-time measurement of inhalation agent consumption.
Reference Key
singh2013journalmeasurement Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Preet Mohinder Singh;Anjan Trikha;Renu Sinha;Anuradha Borle
Journal molecular ecology resources
Year 2013
DOI
10.4103/0970-9185.119160
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.