a comparative study on experimental and simulation responses of cr-39 to neutron spectra from a 252cf source
Clicks: 142
ID: 160276
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
142 views
12 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #26 of 33 articles by views in postepy higieny i medycyny doswiadczalnej (online)
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A simulation of the interaction of neutrons emitted from a 252Cf source with a CR-39 detector is presented in this paper. Elastic and inelastic neutron interactions occur with the constituent materials of the CR-39 detector. Inelastic scatterings only consider (n, a) and (n, p) reactions. Fast neutrons tracks are, mainly, produced by recoil particle tracks in the plastic nuclear track detector as a result of the elastic scattering reaction of neutrons with the constituent materials of the solid-state nuclear track detectors, especially hydrogen nuclei. The energy of the neutron, incident position, direction, and type of interaction were sampled by the Monte Carlo method. The energy threshold, critical angle and scattering angle to the detector surface normal were the most important factors considered in our calculations. The energy deposited per neutron mass unit was calculated. The angular response was determined by both Monte Carlo simulation and experimental results. The number of visible proton tracks and energy deposited per neutron per visible track were calculated and simulated. The threshold energy of the recoil proton as a function of the thickness and incident proton angles was measured by the etchable range of protons at scattering angles, along with the shape and diameter of the track. Experimental and simulations result were in good agreement.
| Reference Key |
mitra2013nucleara
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Ghergherehchi Mitra;Kim Hyun Wook;Kim Yoon Sang;Afarideh Hossein;Chai Jong Seo |
| Journal | postepy higieny i medycyny doswiadczalnej (online) |
| Year | 2013 |
| DOI |
10.2298/NTRP1303293G
|