anterior stromal puncture with staining: a modified technique for preoperative reference corneal marking for toric lenses and its retrospective analyses
Clicks: 173
ID: 158727
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
173 views
23 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #201 of 456 articles by views in Bioinformatics
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 456 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Introduction: Toric intraocular lenses (IOLs) are an effective way of compensating preexisting corneal astigmatism during cataract surgery. To achieve success, it is imperative to align the toric IOLs in desired position and preoperative reference marking is one among the three important steps for accurate alignment. To make the marking procedure simpler and effective, we have modified the conventional three-step slit lamp-based technique. Materials and Methods: Patient is seated in front of the slit lamp and asked to keep the chin over chin rest. A 26-gauge bent needle with tip stained by sterile blue ink marker is used to make anterior stromal puncture (ASP) at the edges of horizontal 180° axis near the limbus. Results: A total of 58 eyes were retrospectively evaluated. Mean (+/-SD) IOL deviation on day 1 and day 30 was 5.7 ± 6.5° and 4.7 ± 5.6°, respectively. Median IOL misalignment on day 1 and day 30 was 3°. Redialing of IOL was required in 2 (3.4%) eyes only, all of which were performed within 1 week of surgery. In total, 2 (3.7%) eyes had a residual astigmatism of − 0.5 Dcyl and − 1.0 Dcyl, respectively. Conclusion: ASP is an effective technique for reference marking, technically simpler and can be practiced by most of the surgeons. It avoids the necessity of high-end sophisticated machinery and gives a better platform for the reference corneal marking along with the benefit of reproducibility and simplicity.
| Reference Key |
bhandari2016indiananterior
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Sahil Bhandari;Manas Nath |
| Journal | Bioinformatics |
| Year | 2016 |
| DOI |
10.4103/0301-4738.191486
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.