evaluation of radiation exposure of urology surgeons and radiology personnel during fluoroscopy guided surgeries at shahid faghihi hospital in shiraz
Clicks: 278
ID: 157642
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
278 views
35 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #28 of 50 articles by views in artificial cells, nanomedicine, and biotechnology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Background & Objective: Long term exposure to ionizing radiation and its complication have always been concerned by medical physicists. Some previous studies have shown that radiation dose to urology surgeons and involved personnel during mini C-arm fluoroscopy guided surgeries exceeds the secure threshold in some cases. In this study, we intend to evaluate the radiation exposure of urology surgeons and radiology personnel and compare these results to the standard thresholds.
Material & Methods: Four urology surgeons, eight residents and eight radiology personnel underwent radiation dosimetry on five different organs during three months. Mentioned surgeons used mini C-arm fluoroscopy and TLD-100s were used for dosimetry.
Results: Calculated mean for accumulative radiation exposure for Urology surgeons, residents and radiology personnel are 174, 198 and 184 milirem, respectively. The absorbed dose for different organs were calculated in descending order at dominant hand, thyroid, subdominant hand, Gonads and Chest wall.
Conclusion: According to the results, radiation exposure during fluoroscopy guided surgeries has not exceeded the standard threshold defined by National Council on Radiation Protection and Measurement (NCRP).
| Reference Key |
movahedi2016journalevaluation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Mohammad Mehdi Movahedi;Alireza Mehdizadeh;Behnam Khalifeh;Samad Amani;Shahram Taeb;Hesamoddin Mostaghimi |
| Journal | artificial cells, nanomedicine, and biotechnology |
| Year | 2016 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.