simultaneous determination of caffeine and theophylline using square wave voltammetry at poly(l-aspartic acid)/functionalized multi-walled carbon nanotubes composite modified electrode
Clicks: 271
ID: 155620
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
271 views
48 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #15 of 46 articles by views in crystals
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A simple and reproducible poly(l-aspartic acid)/functionalized multi-walled carbon nanotubes composite modified glassy carbon electrode, P(LAsp)/f-MWCNTs/GCE, was constructed for simultaneous determination of caffeine and theophylline using square wave voltammetry. The electrode preserves and combines the properties of the individual modifiers synergistically. The electrochemical response of P(LAsp)/f-MWCNTs/GCE was characterized by cyclic voltammetry. A significant enhancement in the peak current response of CF and TP were observed accompanied with a negative shift in peak potential at the composite modified electrode compared to the bare electrode. The prepared P(LAsp)/f-MWCNTs/GCE exhibited excellent SWV response towards the simultaneous detection of CF and TP in the range of 1–150 and 0.1–50μM with limit of detection of 0.28 and 0.02μM (S/N=3), respectively. Real sample analysis has been successfully carried out in green tea, blood serum and pharmaceutical formulation of Panadol extra samples, which revealed good recovery results, 92.0–106%. The proposed sensor also displayed good selectivity, repeatability and reproducibility with appreciable long-term stability, indicating the feasibility and reliability. Keywords: Poly(l-aspartic acid)/functionalized multi-walled carbon nanotubes composite modified electrode, Square wave voltammetry, Simultaneous determination caffeine and theophylline, Green tea, Blood serum, Panadol extra
| Reference Key |
mekassa2017sensingsimultaneous
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Birhanu Mekassa;Merid Tessema;Bhagwan Singh Chandravanshi |
| Journal | crystals |
| Year | 2017 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.