análise biomecânica de variáveis relacionadas à resistência ao arrancamento dos parafusos do sistema de fixação vertebral biomechanical analysis of the variables related to the pullout strength of screws in the vertebral fixation system
Article Quality & Performance Metrics
Readership in this journal
PopularRanked #6 of 69 articles by views in scientific american
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
OBJECTIVE: To observe the relevance of the pilot hole in the different manners of preparation: dull-tipped probe, cutting-tip probe, and burr, for the purpose of evaluating the level of pullout strength of screws with different diameters. METHODS: Screws of 5, 6, and 7 mm were inserted in the bovine bone test samples. The pilot hole was made with the dull-tipped probe, the cutting-tip probe, and burr. The perforation diameter was smaller, equal, and larger than the inner diameter of the screw. Mechanical pullout assays were performed in the three diameters for each manner of preparation of the pilot hole after inserting the implant. The mechanical assays were performed in an Emic®, Software Tesc 3.13 universal machine with load cell of 2000 N, load application speed of 2 mm/min, pre-load of 5 N, and accommodation time of 10 seconds. The property evaluated in the mechanical assays was the maximum pullout strength. RESULTS: In the group with 5 mm and 6 mm screws, and increase was observed in the pullout strength when the pilot hole diameter was smaller than the inner diameter of the screw in all manners of preparation (dull-tipped probe, cutting-tip probe, and burr). No statistical difference was seen in the seven millimeter screw group for all perforation diameters and manners of preparing the pilot hole. CONCLUSION: The pilot hole diameter has an influence upon the pullout strength of the screws in the vertebral fixation system. The making of a pilot hole with diameter larger than the inner diameter of the screw reduces the pullout strength of the implant, irrespective of the manner of preparation of the pilot hole.
| Reference Key |
rosa2008revistaanlise
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Rodrigo César Rosa;Patrícia Silva;Antonio Carlos Shimano;José Batista Volpon;Helton L.A. Defino;Philip Schleicher;Frank Kandziora |
| Journal | scientific american |
| Year | 2008 |
| DOI |
10.1590/S0102-36162008000700005
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.