evaluation of structural changes in the coal specimen heating process and ucg model experiments for developing efficient ucg systems
Clicks: 206
ID: 154670
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
206 views
21 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #261 of 526 articles by views in acs combinatorial science
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 526 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In the underground coal gasification (UCG) process, cavity growth with crack extension inside the coal seam is an important phenomenon that directly influences gasification efficiency. An efficient and environmentally friendly UCG system also relies upon the precise control and evaluation of the gasification zone. This paper presents details of laboratory studies undertaken to evaluate structural changes that occur inside the coal under thermal stress and to evaluate underground coal-oxygen gasification simulated in an ex-situ reactor. The effects of feed temperature, the direction of the stratified plane, and the inherent microcracks on the coal fracture and crack extension were investigated using some heating experiments performed using plate-shaped and cylindrical coal specimens. To monitor the failure process and to measure the microcrack distribution inside the coal specimen before and after heating, acoustic emission (AE) analysis and X-ray CT were applied. We also introduce a laboratory-scale UCG model experiment conducted with set design and operating parameters. The temperature profiles, AE activities, product gas concentration as well as the gasifier weight lossess were measured successively during gasification. The product gas mainly comprised combustible components such as CO, CH4, and H2 (27.5, 5.5, and 17.2 vol% respectively), which produced a high average calorific value (9.1 MJ/m3).
| Reference Key |
deguchi2013energiesevaluation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Gota Deguchi;Koutarou Ohga;Ken-ichi Itakura;Takuya Nakanowataru;Faqiang Su |
| Journal | acs combinatorial science |
| Year | 2013 |
| DOI |
10.3390/en6052386
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.