a theranostic imaging prototype based on sipm detectors for nanoparticles imaging during hyperthermia
Clicks: 243
ID: 152019
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
243 views
37 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #44 of 435 articles by views in acta botânica brasílica
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 435 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The combination of imaging and therapy has opened the very promising Theranostics domain with magnetic hyperthermia being a very promising domain. However, imaging systems should not interact with the magnetic field. In this work we have tested the recent C-series of SensL SiPM with 3mm pixel size, 4×4 arrays, coupled to different scintillators and irradiated with various gamma energies. The evaluation of the SiPM arrays shows that 1x1mm pixel size can be clearly resolved at PET energies for GAGG:Ce and CsI:Na and 1.5×1.5mm in SPECT imaging for CsI:Na. The best energy resolution was measured equal to 10.5% under 511keV irradiation for the 2×2mm GAGG:Ce; 16% under 511keV irradiation for the 1×1mm GAGG:Ce and 22% under 120keV irradiation for the 1×1mm CsI:Na. In addition, measurements with position sensitive photomultipliers have been carried out, to evaluate the effect of the magnetic field on the imaging performance of the system. While the effect of the magnetic field outside the coil is small, optimal images will be obtained if the imaging system is placed inside the coil, something that can be achieved only by using SiPMs.
| Reference Key |
george2016mateca
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Loudos George;Georgiou Maria;Fysikopoulos Eleftherios;Fragogeorgi Eirini |
| Journal | acta botânica brasílica |
| Year | 2016 |
| DOI |
10.1051/matecconf/20164103004
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.