development and validation of spectrofluorimetric and lc–ms/ms methods for the determination of hesperidin in human plasma and pharmaceutical forms
Clicks: 207
ID: 151757
2012
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
5.4
/100
18 views
18 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
The spectrofluorometric method, based on fluorescence properties of aluminium (III)–hesperidin complex, for the determination of hesperidin in human plasma and pharmaceutical forms has been developed and validated. The complex shows strong emission in the presence of surfactant betain sulfonate SB 12 at 476 nm with excitation at 390 nm. Linearity range in pharmaceutical forms of hesperidin was 0.06 – 24.4 μg mL-1 with LOD 0.016 μg mL-1 and LOQ 0.049 μg mL-1. Recovery values in the range 99.3 – 99.7% indicate good accuracy of the method. A linear dependence of the intensity of fluorescence of the complex on the concentration of hesperidin in plasma was obtained in concentration range from 0.1 – 12.2 μg mL-1. The LOD was 0.032 μg mL-1 while LOQ was 0.096 μg mL-1. Recovery values were in the range 98.4 – 99.8%. The reliability of the method was checked by LC-MS/MS method for plasma samples and HPLC/UV method for tablets with direct determination of hesperidin after separation. Linearity range in determination of hesperidin in pharmaceutical forms was obtained in the range from 0.05 to 10.00 μg mL-1. The LOD was 0.01 μg mL-1 and LOQ was 0.03 μg mL-1. Linearity range in plasma determination of hesperidin was 0.02 – 10.00 μg mL-1 with LOD 0.005 μg mL-1 and LOQ 0.015 μg mL-1. Good agreement between two methods indicate the usability of the proposed spectroflurometric method for the simple, precise and accurate determination of hesperidin in clinical and quality control laboratories.
| Reference Key |
a.2012journaldevelopment
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Pavun Leposava A.;Dimitrić-Marković Jasmina M.;Đurđević Predrag T.;Jelikić-Stankov Milena D.;Đikanović Daniela B.;Ćirić Andrija R.;Malešev Dušan L. |
| Journal | meditsinskaia radiologiia |
| Year | 2012 |
| DOI |
10.2298/JSC111005060P
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.