spiral flow tube for contrast medium reduction in coronary ct angiography

Clicks: 276
ID: 151748
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #9 of 39 articles by views in transplant infectious disease : an official journal of the transplantation society

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: To assess the diagnostic performance and enhancement of coronary CT with reduced contrast medium using the spiral flow tube compared with the T-shaped tube. Methods We retrospectively included 444 patients who underwent catheter examination within 2 months after coronary CT. The first 222 patients received 21.0 mgI/kg/s of contrast medium using the T-shaped tube and the injected contrast medium was reduced by 6% (19.8 mgI/kg/s) in the last 222 patients using the spiral flow tube. We compared the per vessel diagnostic performance for detecting obstructive stenosis (≥50%) by catheter examination and the enhancement of proximal coronary arteries. Results The sensitivity, specificity, positive predictive value, negative predictive value and accuracy was 96%, 84%, 72%, 98% and 87% using the spiral flow tube and 93%, 83%, 68%, 97% and 86% using the T-shaped tube, respectively, without significance. The enhancement of left main (spiral flow vs T-shape, 407 ± 53 vs 407 ± 62 HU, p = 0.95) and right coronary (419 ± 58 vs 415 ± 61 HU, p = 0.49) arteries did not show significant difference. Conclusions The spiral flow tube would maintain the diagnostic performance and coronary enhancement with reduced contrast medium compared with the T-shaped tube.
Reference Key
tomizawa2016internationalspiral Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Nobuo Tomizawa;Yayoi Hayakawa;Shinichi Inoh;Takeshi Nojo;Satoshi Uemura;Sunao Nakamura
Journal transplant infectious disease : an official journal of the transplantation society
Year 2016
DOI
https://doi.org/10.17987/icfj.v9i0.375
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.