experimental analysis of a heat cost allocation method for apartment buildings

Clicks: 116
ID: 150553
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #28 of 33 articles by views in zhong yao cai = zhongyaocai = journal of chinese medicinal materials

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The correct estimate of individual thermal energy consumptions, and consequently, a fair heat cost allocation among the residents of apartment buildings with centralized heating systems, represents an important driving force towards energy saving, energy efficiency and the reduction of pollutant emissions. Nowadays, in those contexts where direct heat meters cannot be used because of the layout of the hot water distribution system, electronic Heat Cost Allocators (HCAs) have the highest market share for the assessment of individual thermal energy consumptions. The uncertainty associated with the parameterization of heat cost allocation devices and the installation effects arising in real applications can negatively affect the accuracy of these devices, as far as the estimation of the individual fractions of thermal energy consumption is concerned. This work deals with the experimental analysis of a novel heat cost allocation method for apartment buildings and its comparison with conventional HCAs. The method allows the indirect estimation of the thermal energy exchanged by water radiators without the need for surface temperature measurements, reducing some of the drawbacks associated with the on-site installation. The experimental analysis was carried out in a full-scale central heating system test facility available at the Italian National Metrology Institute (INRIM) and characterized by SI-traceable direct heat meters installed on each water radiator.
Reference Key
saba2017buildingsexperimental Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Fabio Saba;Vito Fernicola;Marco Carlo Masoero;Salvatore Abramo
Journal zhong yao cai = zhongyaocai = journal of chinese medicinal materials
Year 2017
DOI
10.3390/buildings7010020
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.