drying of rhinacanthus nasutus (linn.) kurz. using a solar dryer incorporated with a backup thermal energy storage from wood combustion
Clicks: 286
ID: 149672
2006
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Popular Article
63.7
/100
285 views
230 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
An indirect, natural convection, solar cabinet dryer incorporated with a backup thermal energy storage from wood combustion was designed and tested with the Thai herb, Rhinacanthus nasutus (Linn.) Kurz. Most of Thai herbs are widely used as traditional medicine and drying is an initial step in the production process. Solar dryer with a biomass backup heating system is the most feasible solution to drying in Thailand. In this work, a 4 m x 5 m solar collector was used to absorb solar radiation for heating the incoming air during the daytime, while a biomass burner was used to supply heat when solar energy was not possible. Heat from fuelwood combustion was accumulated in the thermal storage system made of bricks, and was used to heat up the incoming air. Results showed that the herb was dried uniformly and the temperature inside the drying cabinet could be maintained above 50ºC for more than 10 hours. Thermal efficiency when using solar energy was 10.5%, but the value was less than 1% when using the heat from biomass burning. This resulted from the low moisture content of the products after being dried by the solar energy. The dryer is beneficial to the operators, particularly in southern Thailand, where continuous drying is required. This dryer is by no means limited to drying of the herb. Currently, four dryers of the same model have been used by farmer groups in southern Thailand for drying bananas, several types of herbs, fish, and other products. In economic consideration, its payback period is 5.5 years when compared with the LPG-equipped dryer. When the total cost and production capacity are considered, its payback period is about 6 years.
| Reference Key |
tekasakul2006songklanakarindrying
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Perapong Tekasakul;Nattapong Na Nakorn;Gumpon Prateepchaikul;Jiraphong Navasut;Pairoj Kirirat |
| Journal | ferroelectrics |
| Year | 2006 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.