analysis of the metabolic properties of maintenance hemodialysis patients with glucose-added dialysis based on high performance liquid chromatography quadrupole time-of-flight mass spectrometry
Clicks: 235
ID: 148640
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
235 views
38 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #30 of 91 articles by views in liver transplantation : official publication of the american association for the study of liver diseases and the international liver transplantation society
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Li Cui,1 Yu Meng,2 Dan Xu,2 Yanyan Feng,2 Gangyi Chen,3 Bo Hu,2 Guijuan Feng,4 Lianghong Yin2 1Xi'xiang People's Hospital Affiliated to Guangdong Medical College, Shenzhen, People's Republic of China; 2Nephrology Department of the First Hospital Affiliated to Ji'nan University, Guangzhou, People's Republic of China; 3First Hospital of Guangzhou University of Chinese Medicine, 4Assisted Reproductive Centre of the First Hospital Affiliated to Ji'nan University, Guangzhou, People's Republic of China Abstract: The purpose of this study was to compare the metabolic properties of maintenance hemodialysis patients treated with glucose-containing and glucose-free dialysate using metabonomics. Pre- and post-dialysis serum samples from group G (−) using glucose-free dialysate, and group G (+) using glucose-added dialysate (glucose levels were 5.5 mmol/L) were analyzed and tested with high performance liquid chromatography quadrupole time-of-flight mass spectrometry. Orthogonal signal correction–partial least squares discriminate analysis revealed a significant difference in the post-dialysis metabolic properties between samples from the G (−) and G (+) groups, and concentrations of leucine and dihydroxyprostaglandin F2α were higher in the G (+) group than in the G (−) group. However, markers of reactive lipid mobilization and amino acid release, such as bile acids, aspartate, and valine, were lower in the G (+) group than in the G (−) group. There were no significant differences in excitatory neurotransmitters aspartate and phosphorylated anandamide. Use of liquid chromatography-tandem mass spectrometry metabonomics indicated that using glucose-added dialysate was superior to glucose-free dialysate in the protection of the central nervous system of maintenance hemodialysis patients, but had potential risks in stimulating oxidative stress. Keywords: hemodialysis, metabonomics, glucose-added dialysate
| Reference Key |
l2013therapeuticsanalysis
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Cui L;Meng Y;Xu D;Feng YY;Chen GY;Hu B;Feng GJ;Yin LH |
| Journal | liver transplantation : official publication of the american association for the study of liver diseases and the international liver transplantation society |
| Year | 2013 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.