effect of the thermal insulation layer location on wall dynamic thermal response rate under the air-conditioning intermittent operation

Clicks: 277
ID: 148595
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #7 of 16 articles by views in gateways : international journal of community research & engagement

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Although the air-conditioning intermittent operation is widely used in buildings, more attention is focused on the air-conditioning continuous operation in the whole building to simplify energy conservation design, and thereby, the operation method inconsistence of air-conditioning must lead to the large difference between actual value and design value of energy consumption. According to this situation, in order to explore the wall energy conservation difference under the continuous and intermittent operation of air-conditioning, a experiment is built to analyze the effect of the thermal insulation layer location on wall dynamic thermal response rate. Experimental result shows that under the air-conditioning intermittent operation, wall cold storage is the main source of air-conditioning load formed by walls and the wall internal layer has the significant effect on the wall dynamic thermal response performance. And the closer to wall inner surface for the thermal insulation layer, the lower the inner surface temperature and the higher the wall thermal response rate. Meanwhile, the internal thermal insulation wall has the smallest heat flow value, which is less 35–86% than external thermal insulation wall and the sandwich thermal insulation wall, although they have the same heat transfer coefficients.
Reference Key
zhang2017caseeffect Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Lili Zhang;Tao Luo;Xi Meng;Yating Wang;Chaoping Hou;Enshen Long
Journal gateways : international journal of community research & engagement
Year 2017
DOI
10.1016/j.csite.2017.04.001
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.