multicenter evaluation of the qiastat respiratory panel-a new rapid highly multiplexed pcr based assay for diagnosis of acute respiratory tract infections.
Clicks: 162
ID: 148034
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
162 views
21 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #165 of 234 articles by views in ensaio pesquisa em educação em ciências
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 234 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Acute respiratory tract infections (ARTI), including the common cold, pharyngitis, sinusitis, otitis media, bronchiolitis and pneumonia are the most common diagnoses among patients seeking medical care in western countries, and account for most antibiotic prescriptions. While a confirmed and fast ARTI diagnosis is key for antibiotic prescribing, empiric antimicrobial treatment remains common, because viral symptoms are often clinically similar and difficult to distinguish from those caused by bacteria. As a result, inappropriate antibiotic prescriptions are high and in certain settings likely higher than the commonly estimated 30%. The QIAstat Respiratory Panel® assay (QIAstat RP) is a multiplexed in vitro diagnostics test for the rapid simultaneous detection of 21 pathogens directly from respiratory samples, including human mastadenovirus A-G, primate bocaparvovirus 1+2, human coronavirus (HKU1, NL63, OC43, 229E), human metapneumovirus A/B, rhinovirus/enterovirus, influenza A virus (no subtype, subtype H1, H1N1/2009, H3), influenza B virus, human respirovirus 1+3, human orthorubulavirus 2+4, human orthopneumovirus, Bordetella pertussis, Chlamydia pneumoniae, Mycoplasma pneumoniae and Legionella pneumophila. We describe the first multicenter study of 445 respiratory samples, collected through the 2016-2017 and 2018 respiratory seasons, with performance compared against BioFire FilmArray RP v1.7 and discrepancy testing by Seegene Allplex RP. The QIAstat RP demonstrated a positive percentage of agreement of 98.0% (95% CI: 96.0-99.1%) and a negative percentage agreement of 99.8% (95% CI: 99.6-99.9%). With use of this comprehensive and rapid test, improved patient outcomes and antimicrobial stewardship may potentially be achieved.
| Reference Key |
parina2020plosmulticenter
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Marijo Parčina;Uffe Vest Schneider;Benoit Visseaux;Robert Jozić;Irene Hannet;Jan Gorm Lisby |
| Journal | ensaio pesquisa em educação em ciências |
| Year | 2020 |
| DOI |
10.1371/journal.pone.0230183
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.