Ion exchange membranes enhance the electrokinetic in situ chemical oxidation of PAH-contaminated soil.
Clicks: 327
ID: 14786
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
73.3
/100
327 views
268 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #59 of 357 articles by views in Journal of hazardous materials
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 357 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Electrokinetic in situ chemical oxidation (EK-ISCO) could be used to remediate inorganic/organic-contaminated soil. Oxidizing agents were effectively delivered to the contaminated zones through electromigration and the electroosmosis. However, the cathode may react with oxidants, which would reduce the oxidative effect and lead to low contaminant removal rates. In this study, ion-exchange membranes (IEMs) enhanced EK-ISCO was used to remediate polycyclic aromatic hydrocarbons (PAHs) in contaminated soil. IEMs were installed between the electrode compartment and the soil compartment. The results showed that the IEMs could effectively control pH and the oxidation-reduction potential (ORP) changes in the soil column. Placing a cation-exchange membrane (CEM) at the cathode prevented the SO from contacting the cathode and reduced the oxidative loss effect, which meant that PAH removal efficiency significantly improved (from 33.1% to 87.1%). Furthermore, there were minimal changes to the soil properties. Maintaining the soil at a low pH also improved the PAH removal efficiency (93.1%), but the physicochemical properties of the soil significantly changed and a large amount of power was consumed (2015 kWh t). This study indicated that placing a CEM at the cathode improved remediation efficiency, and reduced power consumption and the adverse effects on soil properties during EK-ISCO.
| Reference Key |
xu2019ionjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Xu, Hongting;Song, Yue;Cang, Long;Zhou, Dongmei; |
| Journal | Journal of hazardous materials |
| Year | 2019 |
| DOI |
S0304-3894(19)30996-3
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.