scanning electron microscopy of the trabecular meshwork: understanding the pathogenesis of primary angle closure glaucoma
Clicks: 353
ID: 147697
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
353 views
20 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #55 of 456 articles by views in Bioinformatics
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 456 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Purpose: To study ultrastructural changes of the trabecular meshwork in acute and chronic primary angle closure glaucoma (PACG) and primary open angle glaucoma (POAG) eyes by scanning electron microscopy. Materials and Methods: Twenty-one trabecular meshwork surgical specimens from consecutive glaucomatous eyes after a trabeculectomy and five postmortem corneoscleral specimens were fixed immediately in Karnovsky solution. The tissues were washed in 0.1 M phosphate buffer saline, post-fixed in 1% osmium tetraoxide, dehydrated in acetone series (30-100%), dried and mounted. Results: Normal trabecular tissue showed well-defined, thin, cylindrical uveal trabecular beams with many large spaces, overlying flatter corneoscleral beams and numerous smaller spaces. In acute PACG eyes, the trabecular meshwork showed grossly swollen, irregular trabecular endothelial cells with intercellular and occasional basal separation with few spaces. Numerous activated macrophages, leucocytes and amorphous debris were present. Chronic PACG eyes had a few, thickened posterior uveal trabecular beams visible. A homogenous deposit covered the anterior uveal trabeculae and spaces. Converging, fan-shaped trabecular beam configuration corresponded to gonioscopic areas of peripheral anterior synechiae. In POAG eyes, anterior uveal trabecular beams were thin and strap-like, while those posteriorly were wide, with a homogenous deposit covering and bridging intertrabecular spaces, especially posteriorly. Underlying corneoscleral trabecular layers and spaces were visualized in some areas. Conclusions: In acute PACG a marked edema of the endothelium probably contributes for the acute and marked intraocular pressure (IOP) elevation. Chronically raised IOP in chronic PACG and POAG probably results, at least in part, from decreased aqueous outflow secondary to widening and fusion of adjacent trabecular beams, together with the homogenous deposit enmeshing trabecular beams and spaces.
| Reference Key |
sihota2012indianscanning
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Ramanjit Sihota;Amita Goyal;Jasbir Kaur;Viney Gupta;Tapas C Nag |
| Journal | Bioinformatics |
| Year | 2012 |
| DOI |
10.4103/0301-4738.95868
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.