feature of fire resistance calculation of steel structures with intumescent coating
Clicks: 140
ID: 146797
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
140 views
9 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #217 of 435 articles by views in acta botânica brasílica
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 435 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The problem of estimation of fire resistance of steel frame structures with intumescent coatings is considered. It implies that both physical properties of a covering (its thickness and structure) and mechanical properties of a metal structure change critically at heating. All above changes should be considered to maintain the standard values of fire resistance of a construction at calculation. Usually, known technical characteristics of fire resistance of intumescent coverings are used for estimation of fire resistance of steel structures with intumescent coverings. Importance of taking into account the influence of strength loss time at heating of a steel structure on calculation of fire resistance limit of system “intumescent fireproof coating steel structure” is shown in the article. On an example of calculation of heating time to the critical temperature of steel columns and beams protected by intumescent coating, it is shown that own heating time of steel structures before they lose strength makes 10 to 16 % from a settlement limit of fire resistance. This fact should be considered at the forecast of fire resistance of steel frame structures with intumescent coatings.
| Reference Key |
alexey2018matecfeature
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Vasilchenko Alexey;Otrosh Yuriy;Adamenko Nikolay;Doronin Evgeny;Kovalov Andrey |
| Journal | acta botânica brasílica |
| Year | 2018 |
| DOI |
10.1051/matecconf/201823002036
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.