automatic lung nodule detection using multi-scale dot nodule-enhancement filter and weighted support vector machines in chest computed tomography.
Clicks: 203
ID: 146185
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
203 views
37 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #105 of 234 articles by views in ensaio pesquisa em educação em ciências
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 234 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A novel CAD scheme for automated lung nodule detection is proposed to assist radiologists with the detection of lung cancer on CT scans. The proposed scheme is composed of four major steps: (1) lung volume segmentation, (2) nodule candidate extraction and grouping, (3) false positives reduction for the non-vessel tree group, and (4) classification for the vessel tree group. Lung segmentation is performed first. Then, 3D labeling technology is used to divide nodule candidates into two groups. For the non-vessel tree group, nodule candidates are classified as true nodules at the false positive reduction stage if the candidates survive the rule-based classifier and are not screened out by the dot filter. For the vessel tree group, nodule candidates are extracted using dot filter. Next, RSFS feature selection is used to select the most discriminating features for classification. Finally, WSVM with an undersampling approach is adopted to discriminate true nodules from vessel bifurcations in vessel tree group. The proposed method was evaluated on 154 thin-slice scans with 204 nodules in the LIDC database. The performance of the proposed CAD scheme yielded a high sensitivity (87.81%) while maintaining a low false rate (1.057 FPs/scan). The experimental results indicate the performance of our method may be better than the existing methods.
| Reference Key |
gu2019plosautomatic
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Yu Gu;Xiaoqi Lu;Baohua Zhang;Ying Zhao;Dahua Yu;Lixin Gao;Guimei Cui;Liang Wu;Tao Zhou |
| Journal | ensaio pesquisa em educação em ciências |
| Year | 2019 |
| DOI |
10.1371/journal.pone.0210551
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.