detection of ofloxacin resistance by nitrate reductase assay in mycobacterium tuberculosis isolates from extrapulmonary tuberculosis

Clicks: 282
ID: 145517
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #41 of 129 articles by views in bjog : an international journal of obstetrics and gynaecology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 129 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Context: Increased use of fluoroquinolones to treat community-acquired infections has led to the decreased susceptibility to Mycobacterium tuberculosis. There is a paucity of data on ofloxacin (OFX) resistance detection by nitrate reductase assay (NRA). Hence, the present study was carried out to find the efficacy of NRA for detection of OFX resistance in M. tuberculosis isolated from extrapulmonary tuberculosis (EPTB) cases. Aims: (1) To compare sensitivity, specificity and median time required to obtain results by NRA with economic variant proportion method (PM) for detection of OFX resistance.(2) To determine the extent of OFX resistance in clinical isolates of M. tuberculosis. Settings and Design: Seventy-three M. tuberculosis isolates from cases of EPTB were subjected to economic variant of PM for isoniazid, rifampicin and OFX. NRA was done for detection of OFX resistance. Subjects and Methods: Seventy-three isolates from clinical samples of suspected EPTB received in the Department of Microbiology were included in the study. Drug susceptibility test was performed on Lowenstein–Jensen medium with and without drugs. Statistical Analysis Used: Of turnaround time was done by Mann–Whitney test on SPSS (version 19, released in 2010, IBM Corp, Armonk NY),P < 0.05. Results: OFX resistance was seen in nine isolates. The sensitivity and specificity of OFX resistance by NRA was 100% and 96.87%, respectively. Median time required to obtain results by NRA was 10 days as compared to 28 days by PM. Conclusions: NRA is a specific and sensitive method for detection of OFX resistance in resource-restricted settings.
Reference Key
shrivastava2017indiandetection Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal bjog : an international journal of obstetrics and gynaecology
Year 2017
DOI
10.4103/ijmm.IJMM_16_266
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.