numerical investigation of v-groove air-collector performance with changing cover in bangi, malaysia
Clicks: 47
ID: 145253
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
13.8
/100
47 views
13 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #15 of 16 articles by views in gateways : international journal of community research & engagement
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Air-based solar collectors are the simplest forms of flat plate solar collectors; without complications of introducing water or nanofluids into the process. They are used to raise the entering atmospheric air temperature to a level where it can be used for different low and medium temperature applications. The main components of their design are the collector, absorber and airflow arrangement. However, they exhibit the lowest efficiencies among other collectors. Hence, V-groove absorber designs are implemented to raise the thermal efficiency of air collectors. In this paper, a parametric study on the thermal performance of single-pass solar air collector with a v-groove absorber has been conducted using theoretical model and ran numerically using an excel sheet. The v-groove will enhance the convective heat transfer of the collector; as it has superior performance to flat-plate collectors. Two different cover designs are proposed; one with glass cover and the other with Fresnel lens cover. A comparison of different parameters is presented for various design conditions and operating conditions to drive the efficiency with respect to mass flowrate and incident solar radiation. This paper differs from other works in the literature in that it presents comparison between Fresnel lens and glass cover for V-groove single pass air heater. The results obtained shows that at solar irradiance of 755 W/m2 the collector covered with Fresnel less has the highest efficiency value of 71.18% compared to solar collectors with glass which has efficiency 54.10%. The mass flowrate contributed to efficiency enhancement. Moreover, a case study for Bangi, Malaysia was conducted to numerically test the performance of the two types using real-data from an outdoors test. Highest achieved temperatures from both collectors were around 35.85 °C for the glass-covered type and 38.39 °C for the Fresnel lens covered type. Keywords: Air-collector, Glass cover, Fresnel lens cover, V-groove, Convective heat transfer
| Reference Key |
zulkifle2018casenumerical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Idris Zulkifle;Ali H.A. Alwaeli;Mohd Hafidz Ruslan;Zahari Ibarahim;Mohd Yusof Hj Othman;Kamaruzzaman Sopian |
| Journal | gateways : international journal of community research & engagement |
| Year | 2018 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.